Thank you for your interest in part number A60-3X2, a component manufactured by Buffaloes Fire Pump Inc that we sell here on NSN Parts Finder. For your reference, this item is presented with the NSN 4320-01-155-3956 and features the description “Pump Unit Centrifug.” To request a quote for part number A60-3X2, simply fill out the form below with key details like your budget, required quantity, and anticipated fulfillment timeline. Within 15 minutes of receiving and reviewing your submission, our staff members will present you with competitive purchasing options tailored to your needs. Alternatively, you are also welcome to give us a call or email, and we will gladly guide you through the quotation process or discuss any custom solutions you happen to be seeking.
Note : We Will Not Share Your Information To Any Third Parties.
With a global supply chain and ample purchasing power, we can provide highly competitive pricing and swift lead times on numerous NSN 4320-01-155-3956 products. More than that, we exclusively procure our inventory from reliable manufacturers to guarantee quality, including this component from Buffaloes Fire Pump Inc, which is associated with the CAGECode 62503. Keeping this in mind, get in touch with our specialists today to secure a quote on the FSC 4320 Power And Hand Pumps part number A60-3X2.
MRC | Criteria | Characteristic |
---|---|---|
AHYV | Maximum Discharge Flow Rate | 200.0 GALLONS PER MINUTE |
ELEC | Voltage In Volts | 230.0 AND 460.0 |
AHZE | Centrifugal Pump Design | RADIAL FLOW |
AAYU | Intake Connection Type | ROUND FLANGE |
AHYW | Discharge Pressure | 100.0 POUNDS PER SQUARE INCH GAGE |
ACDC | Current Type | AC |
AHZA | Pumping Element Operating Position | HORIZONTAL |
AHYX | Total Head | 230.000 FEET |
AHZF | Centrifugal Pump Impeller Quantity | 1 |
AHYZ | Operating Speed At Rated Capacity | 3500.0 REVOLUTIONS PER MINUTE |
AAXS | Prime Mover Cooling Medium | AIR |
FAAZ | Phase | THREE |
MRC | Decoded Requirement | Clear Text Reply |
AHZG | Centrifugal Pump Impeller Suction Type | SINGLE |
FREQ | Frequency In Hertz | 60 |
AAXH | Prime Mover Quantity | 1 |
CSYL | Prime Mover Power Rating | 25.0 HORSEPOWER |
AMPS | Current Rating In Amps | 61.6 AND 30.8 |
ADZC | Environmental Protection | SPLASH PROOF |
AAYV | Discharge Connection Quantity | 1 |
ACKL | Media For Which Designed | WATER, SALT |
AKDJ | Prime Mover Type | ELECTRIC MOTOR |
AAYW | Discharge Connection Type | ROUND FLANGE |
AAYD | Stage Quantity | 1 |
AAYT | Intake Connection Quantity | 1 |
AENC | Pump Quantity | 1 |
AENK | Cooling Method | SELF VENTILATED |
AKNA | Inclosure Type | FULLY INCLOSED |
AGAV | End Item Identification | USED AS THE FIRE PUMP ABOARD 180 FT CLASS COAST GUARD VESSELS |