Thank you for your interest in part number AM3333MG6-7-5-250-400-16, a component manufactured by Eaton Corporation that we sell here on NSN Parts Finder. For your reference, this item is presented with the NSN 5925-00-919-8075 and features the description “Circuit Breaker.” To request a quote for part number AM3333MG6-7-5-250-400-16, simply fill out the form below with key details like your budget, required quantity, and anticipated fulfillment timeline. Within 15 minutes of receiving and reviewing your submission, our staff members will present you with competitive purchasing options tailored to your needs. Alternatively, you are also welcome to give us a call or email, and we will gladly guide you through the quotation process or discuss any custom solutions you happen to be seeking.
Note : We Will Not Share Your Information To Any Third Parties.
With a global supply chain and ample purchasing power, we can provide highly competitive pricing and swift lead times on numerous NSN 5925-00-919-8075 products. More than that, we exclusively procure our inventory from reliable manufacturers to guarantee quality, including this component from Eaton Corporation, which is associated with the CAGECode 74193. Keeping this in mind, get in touch with our specialists today to secure a quote on the FSC 5925 Circuit Breakers part number AM3333MG6-7-5-250-400-16.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-919-8075 Item Description: CIRCUIT BREAKER | 5925 | 009198075 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AM3333MG6-7-5-250-400-16 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 7.5 AMPERES AC ALL LOCATIONS |
AKPX | Pole Quantity | 4 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
AJEC | Boss Height | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
TTQY | Terminal Type And Quantity | 8 THREADED STUD |
THSD | Thread Series Designator | UNC |
CPRX | Actuator Position Designation | AT EACH POLE |
CPRT | Manual Actuator Type And Quantity | 4 TOGGLE |
CPRW | Actuator Function | RESET |
ADAT | Body Width | 2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CQJX | Nominal Thread Size | 0.138 INCHES |
AXHR | Mounting Facility Type And Quantity | 8 THREADED HOLE |
ADTV | Case Material | PLASTIC |
AJWX | Mounting Surface To Terminal End Distance | 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM |
ADAQ | Body Length | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CMLP | Thread Quantity Per Inch | 32 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.170 MINIMUM AT 200 PCT ALL LOCATIONS AND 1.700 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, THREE, AND FOUR LINKED |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.