Thank you for your interest in part number LS 29960-2, a component manufactured by Gems Sensors Inc that we sell here on NSN Parts Finder. For your reference, this item is presented with the NSN 5930-01-063-1159 and features the description “Switch Liquid Level.” To request a quote for part number LS 29960-2, simply fill out the form below with key details like your budget, required quantity, and anticipated fulfillment timeline. Within 15 minutes of receiving and reviewing your submission, our staff members will present you with competitive purchasing options tailored to your needs. Alternatively, you are also welcome to give us a call or email, and we will gladly guide you through the quotation process or discuss any custom solutions you happen to be seeking.
Note : We Will Not Share Your Information To Any Third Parties.
With a global supply chain and ample purchasing power, we can provide highly competitive pricing and swift lead times on numerous NSN 5930-01-063-1159 products. More than that, we exclusively procure our inventory from reliable manufacturers to guarantee quality, including this component from Gems Sensors Inc, which is associated with the CAGECode 04034. Keeping this in mind, get in touch with our specialists today to secure a quote on the FSC 5930 Switches part number LS 29960-2.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-063-1159 Item PartTypeName: SWITCH,LIQUID LEVEL | 5930 | 010631159 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
LS-29960-2 | 6 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
ACYN | AC VOLTAGE RATING | 115.0 VOLTS NOMINAL |
ACYN | AC VOLTAGE RATING | 230.0 VOLTS NOMINAL 2ND OPERATING POWER RQMT |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
AFLW | ACTUATION METHOD | BUOYANCY |
ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
APGW | CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.04 AMPERES RESISTIVE LOAD |
APGY | VOLTAGE RATING AT MAXIMUM RATED CURRENT | 120.0 VOLTS |
AWAE | FLOAT QUANTITY | 1 |
AWTN | OPERATING TEMP RATING | 65.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | FLANGE |
BBJX | MOUNTING POSITION | VERTICAL |
BJKC | MAXIMUM CURRENT RATING | 0.08 AMPERES RESISTIVE LOAD |
BJKG | RELAY | NOT INCLUDED |
BJKH | LIQUID TYPE FOR WHICH DESIGNED | HYDRAULIC OIL AND LUBRICATING OIL AND SEA WATER AND VARIOUS FUELS AND WATER |
BJKP | MOUNTING DIMENSIONS | MTD BY FOUR 9/32 IN. DIA HOLES LOCATED ON 3-1/2 IN. DIA BOLT CIRCLE |
BJKQ | TANK INSERTION LENGTH | 5.875 INCHES MINIMUM AND 6.125 INCHES MAXIMUM |
FAAZ | PHASE | SINGLE |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.