Thank you for your interest in part number ALPHA 3807-01GD, a component manufactured by International Power Sources Inc that we sell here on NSN Parts Finder. For your reference, this item is presented with the NSN 6130-01-398-9105 and features the description “Powersupply.” To request a quote for part number ALPHA 3807-01GD, simply fill out the form below with key details like your budget, required quantity, and anticipated fulfillment timeline. Within 15 minutes of receiving and reviewing your submission, our staff members will present you with competitive purchasing options tailored to your needs. Alternatively, you are also welcome to give us a call or email, and we will gladly guide you through the quotation process or discuss any custom solutions you happen to be seeking.
Note : We Will Not Share Your Information To Any Third Parties.
With a global supply chain and ample purchasing power, we can provide highly competitive pricing and swift lead times on numerous NSN 6130-01-398-9105 products. More than that, we exclusively procure our inventory from reliable manufacturers to guarantee quality, including this component from International Power Sources Inc, which is associated with the CAGECode 0JSW7. Keeping this in mind, get in touch with our specialists today to secure a quote on the FSC 6130 Converters Electrical Non Rotating part number ALPHA 3807-01GD.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-398-9105 Item PartTypeName: POWER SUPPLY | 6130 | 013989105 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
ALPHA 3807-01GD | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ANPM | INPUT PHASE | SINGLE 2ND ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 220.0 AC POUNDS PER HOUR DRY 3RD ALTERNATE OPERATING POWER RQMT AND 230.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 3RD ALTERNATE OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 48.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWHC | OUTPUT CONTROL LOCATION | REAR PANEL SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | CONNECTOR,RECEPTACLE SINGLE POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 70.0 AC AMPERES NOMINAL 3RD ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 2ND ALTERNATE OPERATING POWER RQMT |
ABKW | OVERALL HEIGHT | 5.250 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 13.110 INCHES NOMINAL |
ANPM | INPUT PHASE | SINGLE 1ST ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 120.0 AC POUNDS PER HOUR DRY 2ND ALTERNATE OPERATING POWER RQMT AND 130.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND ALTERNATE OPERATING POWER RQMT |
CWKG | VENTILATION DESIGN TYPE | CONVECTION |
ABHP | OVERALL LENGTH | 19.000 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | F-15 |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE 3RD ALTERNATE OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 4TH ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 230.0 AC POUNDS PER HOUR DRY 4TH ALTERNATE OPERATING POWER RQMT AND 250.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 4TH ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 0.0 DC KILOVOLTS MINIMUM SINGLE POWER OUTPUT AND 30.0 DC KILOVOLTS MAXIMUM SINGLE POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 48.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 48.0 HERTZ MINIMUM 3RD ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 3RD ALTERNATE OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 48.0 HERTZ MINIMUM 4TH ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 4TH ALTERNATE OPERATING POWER RQMT |
CWGH | OUTPUT CURRENT RATING | 0.0 DC MILLIAMPERES MINIMUM SINGLE POWER OUTPUT AND 1.5 DC MILLIAMPERES MAXIMUM SINGLE POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 SINGLE POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 70.0 AC AMPERES NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
CWHM | INPUT CURRENT RATING | 70.0 AC AMPERES NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
CWHM | INPUT CURRENT RATING | 70.0 AC AMPERES NOMINAL 4TH ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 1ST ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 3RD ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 4TH ALTERNATE OPERATING POWER RQMT |
FEAT | SPECIAL FEATURES | OUTPUT VOLTAGE ANALOG METER,CONTROL SELECTOR SWITCH,VOLTAGE AND CURRENT ADJUSTABLE,LOCAL CONTROL POTENTIOMETER,ELECTROSTATIC SENSITIVE DEVICE |
APNX | INPUT VOLTAGE RATING | 90.0 AC POUNDS PER HOUR DRY 1ST ALTERNATE OPERATING POWER RQMT AND 110.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST ALTERNATE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1/50.0 DEG CELSIUS |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote