Thank you for your interest in part number 050-005062-001, a component manufactured by Northrop Grumman Systems Corporation that we sell here on NSN Parts Finder. For your reference, this item is presented with the NSN 5950-01-299-1252 and features the description “Transformer Power.” To request a quote for part number 050-005062-001, simply fill out the form below with key details like your budget, required quantity, and anticipated fulfillment timeline. Within 15 minutes of receiving and reviewing your submission, our staff members will present you with competitive purchasing options tailored to your needs. Alternatively, you are also welcome to give us a call or email, and we will gladly guide you through the quotation process or discuss any custom solutions you happen to be seeking.
Note : We Will Not Share Your Information To Any Third Parties.
With a global supply chain and ample purchasing power, we can provide highly competitive pricing and swift lead times on numerous NSN 5950-01-299-1252 products. More than that, we exclusively procure our inventory from reliable manufacturers to guarantee quality, including this component from Northrop Grumman Systems Corporation, which is associated with the CAGECode 26916. Keeping this in mind, get in touch with our specialists today to secure a quote on the FSC 5950 Coils and Transformers part number 050-005062-001.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-299-1252 Item PartTypeName: TRANSFORMER,POWER | 5950 | 012991252 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
050-005062-001 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 0.300 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 1.025 INCHES MINIMUM AND 1.035 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.560 INCHES MINIMUM AND 1.580 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.142 INCHES MINIMUM 2ND GROUP AND 0.152 INCHES MAXIMUM 2ND GROUP |
ACZB | FREQUENCY RATING | 40.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | OPEN |
AKPV | MOUNTING FACILITY QUANTITY | 3 1ST GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 2ND GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE 1ST GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE 2ND GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
CBBL | FEATURES PROVIDED | TINNED WIRE LEADS |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES 1ST GROUP |
CQKH | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE BASE OF AN ISOSCELES TRIANGLE | 1.220 INCHES MINIMUM 1ST MOUNTING FACILITY SINGLE CENTER GROUP AND 1.230 INCHES MAXIMUM 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.86 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 300.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 400.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 500.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 175.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
CRMJ | WINDING POWER RATING | 5.64 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 7.52 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 9.4 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 94.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.320 INCHES MINIMUM 1ST MOUNTING FACILITY SINGLE CENTER GROUP AND 1.330 INCHES MAXIMUM 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | WINDING OPERATING VOLTAGE | 18.80 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 18.80 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 18.80 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 37.60 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 94.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
THSD | THREAD SERIES DESIGNATOR | UNC 1ST GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 11 WIRE LEAD |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.