Thank you for your interest in part number 276-0063-010, a component manufactured by Robert M Hadley Company Inc that we sell here on NSN Parts Finder. For your reference, this item is presented with the NSN 5950-01-342-2782 and features the description “Reactor.” To request a quote for part number 276-0063-010, simply fill out the form below with key details like your budget, required quantity, and anticipated fulfillment timeline. Within 15 minutes of receiving and reviewing your submission, our staff members will present you with competitive purchasing options tailored to your needs. Alternatively, you are also welcome to give us a call or email, and we will gladly guide you through the quotation process or discuss any custom solutions you happen to be seeking.
Note : We Will Not Share Your Information To Any Third Parties.
With a global supply chain and ample purchasing power, we can provide highly competitive pricing and swift lead times on numerous NSN 5950-01-342-2782 products. More than that, we exclusively procure our inventory from reliable manufacturers to guarantee quality, including this component from Robert M Hadley Company Inc, which is associated with the CAGECode 72964. Keeping this in mind, get in touch with our specialists today to secure a quote on the FSC 5950 Coils and Transformers part number 276-0063-010.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-342-2782 Item PartTypeName: REACTOR | 5950 | 013422782 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
276-0063-010 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.300 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 0.410 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.305 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 1.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
AKDX | WINDING QUANTITY | 3 SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT ALL WINDING AND WINDING TURNS SINGLE COMPONENT ALL WINDING |
CRBZ | WINDING OPERATING CURRENT | 125.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT ALL WINDING |
ABHP | OVERALL LENGTH | 0.450 INCHES MAXIMUM |
ABHY | TURN QUANTITY | 12 SINGLE COMPONENT ALL WINDING |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.350 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACYF | INDUCTANCE TYPE | FIXED |
ACYV | INDUCTANCE RATING | 100.00 MICROHENRIES MINIMUM SINGLE COMPONENT ALL WINDING |
CQPZ | WINDING CONDUCTOR SIZE | 0.01003 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT ALL WINDING |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
CBBL | FEATURES PROVIDED | TINNED WIRE LEADS |
CRGS | DC RESISTANCE RATING IN OHMS | 0.060 SINGLE COMPONENT ALL WINDING |
TEST | TEST DATA DOCUMENT | 95105-276-0063 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
TTQY | TERMINAL TYPE AND QUANTITY | 6 PIN |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote